CA8336-4X-MA193-250
RÉSUMÉ TECHNIQUE CA8336-4X-MA193-250 :
The CHAUVIN ARNOUX CA8336 is a power meter suitable for single-phase and three-phase systems. It can measure AC and DC voltages up to 1000V. It is designed to handle currents up to 10kA, offering an Inrush function for accurate measurements during start-up. It also features a USB interface for easy connection.
Le CHAUVIN ARNOUX CA8336 est un wattmètre de puissance pour systèmes monophasés et triphasés. Voici ses caractéristiques techniques :
Type : Analyseur de puissance / qualité d’énergie
Applications : Réseaux monophasés et triphasés
Voltage channels: 4
Current channels: 4
Maximum voltage: 1000 V AC / DC
Maximum current: 10 kA AC / DC
Inrush function: Yes
Enregistrement : transitoires, alarmes et formes d’onde
Affichage : écran TFT couleur
Interface: USB
Battery life: approx. 13 h
Catégorie de mesure : CAT III 1000 V / CAT IV 600 V
Logiciels : PAT (standard) / Dataview® (option)
Le Chauvin Arnoux C.A 8336 Qualistar+ est un analyseur de puissance et de qualité d’énergie destiné au diagnostic et à la maintenance des installations électriques monophasées et triphasées. Il permet d’obtenir une analyse complète des paramètres électriques d’un réseau afin d’identifier les anomalies, d’optimiser les performances et de réaliser un bilan énergétique des installations.
L’instrument mesure simultanément de nombreux paramètres électriques tels que la tension, le courant, la puissance et les perturbations du réseau. Il intègre des fonctions avancées telles que la mesure Inrush et TrueInrush pour l’analyse des courants de démarrage, ainsi que l’enregistrement des transitoires, alarmes et formes d’onde.
Le C.A 8336 dispose de 4 voies de mesure en tension et 4 voies en courant, permettant l’analyse complète des réseaux triphasés. Son écran couleur TFT facilite la visualisation des résultats et l’interface permet un accès direct aux fonctions de configuration et aux mesures. L’appareil est conçu pour une utilisation sur le terrain avec une autonomie batterie d’environ 13 heures.
Les données mesurées peuvent être transférées via USB et analysées à l’aide des logiciels PAT (fourni) et Dataview® (option), permettant la configuration de l’instrument, l’analyse des mesures et la génération de rapports.
TYPICAL USE AND SECTOR
Pour CHAUVIN ARNOUX CA8336-4X-MA193-250
The CA8336 + 4X - MA193-250 power meter lets you analyse your systems and optimise your test cycles.
This refurbished instrument offers performance comparable to new and helps to reduce acquisition costs.
Applications :
- RF / microwave
- Networks & telecoms
- Electricity & testing
- Quality Control & Metrology
Sectors :
- Energy (production & distribution)
- Telecoms & networks
Designed for :
- Test and Measurement Engineer
- Quality manager
This reconditioned equipment can be made available quickly with ISO 17025 verification, and combines reliability, economy and durability.
How do you choose your Keysight or Teledyne LeCroy oscilloscope for monitoring complex signals?
Education & teaching
Metrology & accredited laboratories
Telecoms & networks
How do you choose between a portable calibrator and a laboratory calibrator to combine precision and mobility?
Energy (production & distribution)
Industrial maintenance
Metrology & accredited laboratories
Hire or buy a measuring instrument? The real profitability figures
Building & infrastructure
Industrial maintenance
Telecoms & networks

ANY DOUBTS ABOUT A BRAND?
A REFERENCE YOU CAN'T FIND?
Our role does not end with the models displayed.
Some references are not listed, others can be sourced, replaced or adapted to your requirements.Contact us if you are looking for a particular device or if you need compatibility advice.
practical questions about Electrical Test and Measurement
01
Why can an electrical measurement be accurate... but not usable?Because a correct value isolated from its context has little meaning. The actual load, the temperature, the transient regime or the connection mode all have a major influence on interpretation. In electrical testing, relevance depends as much on the measurement conditions as on the intrinsic accuracy of the instrument.
02
What's the difference between measuring to diagnose and measuring to certify?Diagnosis aims to understand a behaviour or locate a fault, and tolerates a certain methodological flexibility. Certification, on the other hand, requires strict procedures, traceable instruments and documented repeatability. The same device can be used for both purposes, but not without adapting the protocol and the level of requirements.
03
Why is safety class as critical as precision?Because reliable measurement should never be at the expense of operator safety. An unsuitable CAT class can expose you to destructive overvoltages, even with a very accurate instrument. In an industrial or energy environment, electrical robustness often takes precedence over the last digit of resolution.
04
When is a specialised instrument preferable to a universal multimeter?As soon as the measurement becomes critical or repetitive. Micro-ohmmeters, megohmmeters or power analysers offer dedicated methods that are more stable and more reproducible than measurements taken with a general-purpose tool. They reduce interpretation errors and provide greater security for technical decisions.
05
Is reconditioned electrical equipment suitable for demanding environments?Yes, as long as it is requalified and documented. Electrical instruments are based on stable, proven architectures. Serious reconditioning, including functional and metrological verification, can deliver performance levels that are suitable for maintenance, production and R&D, with better control of lead times and costs.
Our buying guides and case studies
How to choose a reconditioned oscilloscope: 5 criteria that can't be mistaken
A reconditioned oscilloscope allows you to keep a bench operational, avoid manufacturer delays and control a technical budget without losing reliability. It's a useful solution when the aim is to quickly replace a critical device while retaining the same measurement procedures and compatibility with the existing equipment.
MBDA case study: how a reconditioned RF generator saved a critical test bench
In less than thirty days, Axitest secured two reconditioned Rohde & Schwarz RF generators for an MBDA test bench that had become unusable.
How do you choose your Keysight or Teledyne LeCroy oscilloscope for monitoring complex signals?
The two giants of electronic measurement, Keysight (direct heir to HP and Agilent) and Teledyne LeCroy, have occupied a central place in R&D, teaching and metrology laboratories for decades. But while their instruments may seem comparable, their philosophies and strengths differ profoundly. This article will help you to understand their differences...
Customer case study: quality control of electrical cables at LAPP MULLER using reconditioned equipment
In the electrical wiring industry, every continuity or insulation test determines the safety and performance of installations.
How to prepare for a COFRAC audit with reconditioned instruments: 6 key steps
A COFRAC audit is not just an administrative control; it is an examination of technical competence and metrological traceability. The use of reconditioned instruments is not an obstacle if each stage of preparation is controlled. With rigorous organisation, a well-monitored reconditioned instrument can be easily integrated into the ISO 17025 standard.
How a CNRS laboratory avoided 4 months of downtime and €91,000 in additional costs thanks to a reconditioned test device
A CNRS laboratory was able to keep its measurement chain operational by replacing an Agilent E4446A spectrum analyser that had broken down with a reconditioned model delivered in 48 hours.
5 tips to extend the lifespan of your reconditioned appliances
Refurbished equipment retains all its technical value if it is properly maintained. With a few simple preventive maintenance and metrological checks, it is possible to significantly extend its lifespan and guarantee its reliability.
Customer case: takeover of measurement equipment at Airbus
Taking back measurement equipment at Airbus involved inventorying, sorting and upgrading equipment accumulated over several programmes. Each piece of equipment was directed towards reuse, repair or responsible dismantling with Ateliers Sans Frontières, then documented in a complete traceability system.